Tuba Denizcilik'e ait 4189 GRT'luk Türk bayraklı "TEK BABA" isimli kuruyük gemisi İspanya'nın Cadiz Limanı'nda Paris MoU çerçevesinde eksikliklerden dolayı iki gün tutuklu kaldı.
TEKBABA'nın tutulması ile birlikte, Paris Memorandumu çerçevesinde 2007 yılının ilk üç ayında Avrupa limanlarında tutulan gemi sayısı 10 (ON) oldu.
TEK BABA |
Inspection details : | |
Date of first boarding : | 19/03/2007 |
Date of final boarding : | 20/03/2007 |
Port of inspection : | Cadiz, Spain. |
Type of inspection : | More detailed inspection |
Nb of deficiency(ies) : | 7 |
Nb of deficiency(ies) ground(s) for detention : | 3 |
Duration of detention : | 2 days |
Ship's particulars at the time of inspection : | |
IMO number : | 9045730 |
Name : | TEK BABA |
Flag : | Turkey |
Callsign : | TCCW7 |
Ship type : | General cargo - multipurpose ship |
Gross tonnage : | 4189 |
Keel date : | 1990
|
Classification society : | |
- Class certificate issued by Bureau Veritas (BV), classification society responsable for issuance of class certificate as at date of first boarding |
|
Statutory certificates : |
- International ship security certificate is issued by Turkish Lloyd (TL) |
- Safety management certificat (SMC) is issued by Turkish Lloyd (TL) last survey in Turkey on 26/12/2006 by Turkish Lloyd (TL) |
- Document of compliance (DoC) is issued by Turkish Lloyd (TL) last survey in Turkey on 05/12/2006 by Turkish Lloyd (TL) |
- Load lines certificates is issued by Bureau Veritas (BV) last survey in Turkey on 24/11/2006 by Bureau Veritas (BV) |
- Oil pollution prevention (iopp) is issued by Bureau Veritas (BV) last survey in Turkey on 24/11/2006 by Bureau Veritas (BV) |
Ship manager | |
- Tuba Denizcilik Sanayi ve Tic., sti. guzelyali mah. sahilyolu cad. yakut sok. eminali, apt. no. 26/8 pendik 34903-istanbul, Turkey |
|
Charterer | |
- tuba denizcilik sanayi ve. tic, istanbul, Turkey |
|
Areas inspected : |
- Accommodation and galley |
- Engine and steering room |
- Navigation bridge |
- Outside decks and forecastle |
Operational controls carried out | |
- Communication equipment |
|
- Emergency fire pump |
|
- Emergency generator |
|
- Emergency steering |
|
- Other |
|
- 15 ppm OWS tested |
|
Deficiencies : | |
- Fire safety measures, Fire detection , Not as required, ground for detention |
|
- Fire safety measures, Fire-dampers, Inoperative, ground for detention |
|
- Food and catering, Other (food) |
|
- Life saving appliances , Inflatable liferafts |
|
- MARPOL annex I, Control of discharge |
|
- MARPOL annex I, Retention of oil on board, Not as required, ground for detention |
|
- Radiocommunications, Facilities for reception of marine safety inform. |
|
Denizhaber.com.tr